BLF-455-100 fiber output blue semiconductor laser has good beam quality, sufficient spot homogenization, and high electro-optical efficiency. Standard fiber optic output interface, easy to integrate into the system, widely used in low-power precision welding of non-ferrous metals, etc. This laser has a center wavelength of 455 ± 10nm and can be operated in either continuous or modulated mode. Its maximum continuous output power is greater than 100W and it can be used for welding ultra-thin metal materials such as solder, gold foil, copper foil, and aluminum foil.
Application Area
BLF-455-100 fiber output blue semiconductor laser has good beam quality, sufficient spot homogenization, and high electro-optical efficiency. Standard fiber optic output interface, easy to integrate into the system, widely used in low-power precision welding of non-ferrous metals, etc.
This laser has a center wavelength of 455 ± 10nm and can be operated in either continuous or modulated mode. Its maximum continuous output power is greater than 100W and it can be used for welding ultra-thin metal materials such as solder, gold foil, copper foil, and aluminum foil.
| Parameter Category | Specific Parameter | Parameter Value |
|---|---|---|
| Product Model | BLF-455-100 | - |
| Optical Parameters | Operating Mode | Continuous / Pulsed (Duty Cycle 0.1-100%) |
| Central Wavelength | 455±10nm | |
| Maximum Continuous Output Power | >100W | |
| Beam Quality | 40mm·mrad | |
| Optical Fiber | 400μm, 0.22NA | |
| Fiber Length | 5m / Customizable | |
| Fiber Interface | D80 | |
| Power Instability | ≤2%@RMS | |
| Power Adjustment Range | 10%-100% | |
| Modulation Frequency | 40Hz~1kHz or CW | |
| Electrical Parameters | Power Supply | AC220V±15%, 50Hz |
| Control Method | RS232 Serial Port / Analog Signal | |
| Cooling Parameters | Cooling Method | Water Cooling |
| Laser Cooling Pipe Size | φ12 (Outer) × φ8 (Inner) | |
| Cooling Capacity Requirement | ≥0.5kW | |
| Head Pressure | ≥10m | |
| Cooling Water Temperature | 20℃ | |
| System Parameters | Operating Ambient Temperature | 5-35℃ |
| Operating Ambient Humidity | ≤70%RH@25℃ | |
| Fiber Bending Radius | ≥20cm |